Rheem Logo Background

CAD/BIM

  • All models feature Scroll ® compressors for maximum efficiency and quiet operation.
  • Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes.
  • Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork.
  • Side and down discharge options available on all models.
  • Easily accessible blower section complete with slide-out blower.
  • Externally mounted refrigerant connections are conveniently located for easy service diagnostics.
Unit of Measure

Gross Cooling Capacity

N/A 35000 Btu10.25 kW3 TR

EER

N/A 11

SEER

N/A 14

Nominal CFM

N/A 1200 ft³/min566 L/s

AHRI Rated CFM

N/A 1300 ft³/min613 L/s

AHRI Net Cooling Capacity

N/A 34200 Btu10.02 kW

Net Sensible Capacity

N/A 27500 Btu8.06 kW

Net Latent Capacity

N/A 6700 Btu1.96 kW

Net System Power

N/A 2.96 kW

Voltage

N/A 208 to 230 V

Frequency

N/A 60 Hz

Number of Phases

N/A 1

Minimum Circuit Ampacity

N/A 27 A

Overcurrent Protection [Min]

N/A 35 A

Overcurrent Protection [Max]

N/A 40 A

Compressor Type

N/A Single-Stage Scroll

Sound Level

N/A 76 dB

Refrigerant Type

N/A R-410A

Refrigerant Charge

N/A 5216 g184 oz

Weight

N/A 230 kg508 lb

Shipping Weight

N/A 519 lb235 kg

High Temp. Rating

N/A 33000 Btu9.67 kW

High Temp. Rating - System Power

N/A 2.97 kW

High Temp. Rating - System Power - COP

N/A 3.4

Low Temp. Rating

N/A 18000 Btu5.27 kW

Low Temp. Rating - System Power

N/A 2.72 kW

Low Temp. Rating - System Power - COP

N/A 2

HSPF

N/A 8

Fin Type

N/A Louvered

Tube Type

N/A Rifled

MicroChannel Depth

N/A 0.375 in9.5 mm

Face Area

N/A 16.32 ft²1.52 mm²

Rows

N/A 2

FPI

N/A 22

Refrigerant Control

N/A TX Valves

Fin Type

N/A Louvered

Tube Type

N/A Rifled

MicroChannel Depth

N/A 0.375 in9.5 mm

Face Area

N/A 7.39 ft²0.69 mm²

Rows

N/A 2

FPI

N/A 15

Refrigerant Control

N/A TX Valves

Drain Connection No.

N/A 1

Drain Connection Size

N/A 0.75 in19.05 mm

Type

N/A Propeller

No. Used

N/A 1

Diameter

N/A 22 in558.8 mm

Drive Type

N/A Direct

No. Speeds

N/A 1

CFM

N/A 2700 ft³/min1274 L/s

No. Motors

N/A 1

Horsepower

N/A 1/3 hp

Motor RPM

N/A 1075

Type

N/A FC Centrifugal

No. Used

N/A 1

Diameter

N/A 10x9 in254x229 mm

Drive Type

N/A Direct

No. Speeds

N/A Multiple

No. Motors

N/A 1

Horsepower

N/A 1/2 hp

Motor RPM

N/A 1050

Motor Frame Size

N/A 48 in

Type

N/A Field Supplied

Furnished

N/A No

No. Filters

N/A 1

Recommended Size

N/A 1x24x24 in25x610x610 mm

Depth

N/A 52 7/16 in

Width

N/A 47 1/2 in

Height

N/A 41 in

N/A

  • All models feature Scroll® compressors for maximum efficiency and quiet operation. This unit contains a special scroll compressor that is designed specifically to operate with R-410A Refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise.
  • Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes.
  • One-piece top with a deep flange to help keep water out of the unit.
  • Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork.
  • Access panels have “weep holes” and channels to further help manage water run-off.
  • Side and down discharge options available on all models. (Shipped Downflow Standard).
  • Easily accessible blower section complete with slideout blower.
  • Refrigerant connections are conveniently located for easy service diagnostics. Low pressure/loss of charge protection is standard on all models.
  • Supplemental electric heat strips up to 15 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring makes installation even easier.
  • Easily accessible control box. Package heat pump utilizes demand defrost control which monitors the outdoor ambient temperature, outdoor coil temper - ature, and compressor run-time to determine when a defrost cycle is required.
  • Thermal Expansion Valve standard on all models for superior superheat control, reliability, and energy efficiency at all operating conditions.
  • Filter Drier Standard on all models (not shown).
  • Rugged Baserail for improved installation and handling.
  • Reversing valve directs flow of refrigerant and reverses the refrigerant flow when heating is required.

©Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company.